Electrical and Electronic Engineering, Renewable Energy, Sustainability and the Environment, Industrial and Manufacturing Engineering, Multidisciplinary
6
Scopus Publications
173
Scholar Citations
6
Scholar h-index
3
Scholar i10-index
Scopus Publications
Optimization of Power Generation Using the Tip Speed Ratio Method in a WECS Equipped with PMSG Denisia De Vasconcelos Mota, Alana De Oliveira Ferro, Vanessa Siqueira De Castro Teixeira, Lucas Taylan Ponte Medeiros, Leonardo Pires De Sousa Silva, Adson Bezerra Moreira Cobep 2023 17th Brazilian Power Electronics Conference and Spec 2023 8th IEEE Southern Power Electronics Conference Proceedings, 2023 This research investigates a Wind Energy Conversion System (WECS) composed of a Permanent Magnet Synchronous Generator (PMSG), a back-to-back converter, a wind turbine, and a Maximum Power Point Tracking (MPPT) algorithm. The MPPT is based on the Tip Speed Ratio (TSR) method that, for each wind speed, operates by adjusting the generator rotational speed. Therefore, wind turbine delivers the maximum available power at that speed. The system was implemented in the MATLAB/Simulink software, and the results was consistent: for an optimal wind speed of 12 m/s, the PMSG rotor achieves nominal speed and the developed power by the turbine is close to the nominal power of the PMSG. The techniques and methods employed can contribute to works in intention of efficiency and overall performance of wind energy systems.
Wind power system connected to the grid from Squirrel Cage Induction Generator (SCIG) Angelo Marcilio M. dos Santos, Lucas Taylan P. Medeiros, Leonardo P. S. Silva, Ildenor Davi S. Junior, Vanessa Siqueira de C. Teixeira, Adson Bezerra Moreira 2019 IEEE 15th Brazilian Power Electronics Conference and 5th IEEE Southern Power Electronics Conference Cobep Spec 2019, 2019 The main contribution of this paper is to present a methodology proposal for the development of active and reactive power control of a wind power generation system connected to the grid using the three-phase induction generator with a squirrel cage rotor (SCIG). The SCIG stator terminals are connected to electric grid before the inductive filter using an AC/DC/AC power converter topology, called back-to-back, while the rotor terminals are short circuited, so that the SCIG's active and reactive power control techniques are presented. The control of grid side converter (GSC) is presented, responsible for the power control and also for keeping the DC bus voltage constant. The control of induction generator side converter (IGSC) is presented also, in which vector control is used in rotor variables, so that the SCIG is controlled through the torque references and magnetizing current. The studied system was mathematically modeled and simulated using Matlab/Simulink software.
Power Control and Harmonic Current Mitigation from a Wind Power System with PMSG Leonardo P. S. Silva, Denisia de V. Mota, Flavia P. Ruiz, Levy R. Cavalcante, Lucas Taylan P. Medeiros, Vanessa S. C. Teixeira, Adson B. Moreira 2019 IEEE 15th Brazilian Power Electronics Conference and 5th IEEE Southern Power Electronics Conference Cobep Spec 2019, 2019 This paper describes a wind power system working with control of active and reactive power as well as harmonic current compensation. Power control is made through stator flux oriented in machine-side converter. The active filtering is done by grid-side converter (GSC) causing to grid current waveform without distortions. The algorithm applied for harmonic mitigation has shown to be effective in improving of power quality. Simulation results confirm the effectiveness of the proposed research, since through the power control of permanent magnet synchronous generator (PMSG) and harmonic compensation on GSC was possible to deliver of power to electric grid, satisfactorily.
Control of powers for wind power generation and grid current harmonics filtering from doubly fed induction generator: Comparison of two strategies Adson Bezerra Moreira, Tarcio Andre Dos Santos Barros, Vanessa Siqueira De Castro Teixeira, Ramon Rodrigues De Souza, Marcelo Vinicius De Paula, Ernesto Ruppert Filho IEEE Access, 2019 Two strategies for wind power systems that simultaneously adjust the powers generation from doubly fed induction generator and achieves grid currents harmonic filtering are presented in this paper. The harmonic mitigation function is developed by algorithms proposed for compensating harmonics from the grid side converter. The quality of power is substantially enhanced. The generator side converter regulates the active and reactive powers that are supplied to the electric grid by the stator flux oriented control. This paper presents a novel control system for power generation and electric grid harmonic compensation, which is described and validated through comparison with other strategies. A harmonic filtering behavior analysis for some operation points using the novel strategy is presented. The proposed system efficiency is verified through simulation and experimental results. The grid current THD when none of the proposed strategies are applied is 17.21%. The THD is reduced to 5.68% when strategy 1 is applied. When strategy 2 is used the THD is decreased to 3.18%.
Methodology for the electromagnetic design of the axial-flux c-core switched reluctance generator Vanessa Siqueira De Castro Teixeira, Tarcio Andre Dos Santos Barros, Adson Bezerra Moreira, Ernesto Ruppert Filho IEEE Access, 2018 The main contribution of this paper is to present a methodology proposal for the electromagnetic design of the axial-flux switched reluctance generator with C core (C-SRG). The proposed methodology focuses on different aspects. First, initial C-core dimensions are obtained from analytic equations and design considerations from the traditional switched reluctance machines. Then, a 2-D finite-element method (FEM) model is used to determine the final constructive parameters of the C-SRG coupled with an iterative optimization process. From the proposed design methodology, a C-core prototype of the generator was built, and the static results were obtained. The C-SRG operational analysis compares the experimental results to the simulations results, which uses a model based on FEM that well represents the nonlinearities of the system. The simulated and experimental results attested the viability and efficiency of the proposed methodology to design the C-SRG for wind power generation.
Design, optimization and analysis of the axial C-core Switched Reluctance Generator for wind power application Vanessa Siqueira de Castro Teixeira, Ernesto Ruppert Filho, Tarcio Andre dos Santos Barros, Adson Bezerra Moreira 2015 International Conference on Renewable Energy Research and Applications Icrera 2015, 2015 Switched reluctance generator (SRG) has been covered in several researches in the last two decades. These kind of machine is very promising for wind power application due to their low cost, high efficiency and high power density per volume. On the other hand, lots of researches are dedicated to the study and project of traditional SRG (radial flux). This article presents the electromagnetic design and optimization of the Axial Switched Reluctance Generator with C Core (C-SRG) using finite element method. Moreover, in order to better analyze the dynamic behavior of the C-SRG, a co-simulation was developed using the software Maxwell 3D and Simplorer. The simulation results indicate that the methodology adopted was suitable and can be applied to C-SRG electromagnetic design.
RECENT SCHOLAR PUBLICATIONS
Optimization of power generation using the tip speed ratio method in a wecs equipped with pmsg DDV Mota, ADO Ferro, VSDC Teixeira, LTP Medeiros, LPDS Silva, ... 2023 IEEE 8th Southern Power Electronics Conference and 17th Brazilian Power … , 2023 2023 Citations: 1
Control of scig based on wind energy conversion system with bess ÂMM dos Santos, RPC Pacífico, NS Costa, MVS de França, VSC Teixeira, ... 2023 IEEE 8th Southern Power Electronics Conference and 17th Brazilian Power … , 2023 2023 Citations: 3
Metodologia e Projeto de Controle de Potências para Geração Eólica com o PMSG e Filtragem de Corrente Harmônica LP de Sousa Silva, AB Moreira, LTP Medeiros, VSC Teixeira Congresso Brasileiro de Automática-CBA 3 (1) , 2022 2022
Técnicas de controle aplicadas a um sistema eólico equipado com o PMSG com função de filtragem de corrente harmônica da rede Sob distorções na tensão da rede Control techniques … LP de Sousa Silva, AB Moreira, D de Vasconcelos Mota, LTP Medeiros Brazilian Journal of Development 8 (5), 33435-33456 , 2022 2022
Power Control for a Wind Power Generation from SCIG and Harmonic Current Filtering ÂMM dos Santos, VSC Teixeira, RPC Pacífico, LPS Silva, MVS França, ... Congresso Brasileiro de Automática-CBA 2 (1) , 2020 2020
GERAÇÃO DE ENERGIA EÓLICA A PARTIR DO GERADOR SÍNCRONO DE IMÃ PERMANENTE CONECTADO À REDE ELÉTRICA LP de Sousa Silva, LR Cavalcante, D de Vasconcelos Mota, LT Medeiros, ... Anais Congresso Brasileiro de Energia Solar-CBENS , 2020 2020
Controle de potências para geração eólica com gerador de indução com rotor gaiola de esquilo (GIGE) ÂMM dos Santos, MVS de França, LT Medeiros, RC Pacífico, ... Anais Congresso Brasileiro de Energia Solar-CBENS , 2020 2020
Power Control for a Wind Power Generation from SCIG and Harmonic Current Filtering ÂMM Santos, RPC Pacífico, LPS Silva, MVS França, VSC Teixeira, ... Sociedade Brasileira de Automática (SBA)-https://www. sba. org. br/; Galoá … , 2020 2020
Sistema de Geração de Energia Eólica com Filtro Ativo Paralelo a partir do Gerador Síncrono de Imã Permanente Conectado à Rede Elétrica LP de Sousa Silva, D de Vasconcelos Mota, LR Cavalcante, ... Simpósio Brasileiro de Sistemas Elétricos-SBSE 1 (1) , 2020 2020 Citations: 1
Controle de Potências para Geração Eólica e Filtragem de Corrente Harmônica com Gerador de Indução Gaiola de Esquilo ÂMM dos Santos, LPS Silva, LTP Medeiros, MVS França, VSC Teixeira, ... Simpósio Brasileiro de Sistemas Elétricos-SBSE 1 (1) , 2020 2020
Power control and harmonic current mitigation from a wind power system with PMSG LPS Silva, DV Mota, FP Ruiz, LR Cavalcante, LTP Medeiros, ... 2019 IEEE 15th Brazilian Power Electronics Conference and 5th IEEE Southern … , 2019 2019 Citations: 3
Wind power system connected to the grid from Squirrel Cage Induction Generator (SCIG) ÂMM dos Santos, LTP Medeiros, LPS Silva, IDS Junior, VSC Teixeira, ... 2019 IEEE 15th Brazilian Power Electronics Conference and 5th IEEE Southern … , 2019 2019 Citations: 6
Método analítico eficiente para o cálculo das indutâncias em máquinas de relutância variável com núcleo do tipo c LPF Gomes Filho, VSC Teixeira, AB Moreira, TAS Barros, E Ruppert Filho Eletrônica de Potência 24 (3), 277-286 , 2019 2019
Control of powers for wind power generation and grid current harmonics filtering from doubly fed induction generator: Comparison of two strategies AB Moreira, TADS Barros, VSDC Teixeira, RR De Souza, MV De Paula, ... IEEE access 7, 32703-32713 , 2019 2019 Citations: 57
Método analítico eficiente para o cálculo das indutâncias em máquinas de relutância variável com núcleo do tipo C LPF Gomes, VS de Castro Teixeira, AB Moreira, TA dos Santos Barros, ... Eletrônica de potência= Brazilian journal of power electronics , 2019 2019
Robustness and ethanol production of industrial strains of Saccharomyces cerevisiae using different sugarcane bagasse hydrolysates VS Teixeira, SPH Azambuja, PH Carvalho, FAA Costa, PR Kitaka, ... Journal of applied biotechnology , 2019 2019 Citations: 3
Methodology for the electromagnetic design of the axial-flux C-core switched reluctance generator VSDC Teixeira, TADS Barros, AB Moreira, E Ruppert Filho IEEE access 6, 65463-65473 , 2018 2018 Citations: 16
Gerador de relutância variável com núcleo do tipo C: aspectos construtivos e operacionais= C-Core switched reluctance generator: constructive and operational aspects VS de Castro Teixeira [sn] , 2018 2018
Power control for wind power generation and current harmonic filtering with doubly fed induction generator AB Moreira, TAS Barros, VSC Teixeira, E Ruppert Renewable energy 107, 181-193 , 2017 2017 Citations: 35
Aplicação de controle de potências para a geração eólica e filtragem de corrente harmônica com gerador de indução duplamente alimentado. AB Moreira, TAS Barros, VS Castro, E Ruppert Filho 2017 Citations: 1
MOST CITED SCHOLAR PUBLICATIONS
Control of powers for wind power generation and grid current harmonics filtering from doubly fed induction generator: Comparison of two strategies AB Moreira, TADS Barros, VSDC Teixeira, RR De Souza, MV De Paula, ... IEEE access 7, 32703-32713 , 2019 2019 Citations: 57
Power control for wind power generation and current harmonic filtering with doubly fed induction generator AB Moreira, TAS Barros, VSC Teixeira, E Ruppert Renewable energy 107, 181-193 , 2017 2017 Citations: 35
Methodology for the electromagnetic design of the axial-flux C-core switched reluctance generator VSDC Teixeira, TADS Barros, AB Moreira, E Ruppert Filho IEEE access 6, 65463-65473 , 2018 2018 Citations: 16
Design, optimization and analysis of the axial C-core switched reluctance generator for wind power application VS de Castro Teixeira, E Ruppert Filho, TA dos Santos Barros, ... 2015 International Conference on Renewable Energy Research and Applications … , 2015 2015 Citations: 8
Wind power system connected to the grid from Squirrel Cage Induction Generator (SCIG) ÂMM dos Santos, LTP Medeiros, LPS Silva, IDS Junior, VSC Teixeira, ... 2019 IEEE 15th Brazilian Power Electronics Conference and 5th IEEE Southern … , 2019 2019 Citations: 6
Sistema automático de caracterização de máquinas a relutância variável e modelagem não linear por Interpolações utilizando smoothing splines PS Nascimento Filho, AB Moreira, VSC Teixeira, MG Villalva, E Ruppert Eletrônica de Potência 20 (2), 140-150 , 2015 2015 Citations: 6
Harmonic current compensation and control for wind power generation with doubly fed induction generator AB Moreira, TAS Barros, VSC Teixeira, E Ruppert Proc. IEEE/IAS Int. Conf. Ind. Appl.(INDUSCON), 1-8 , 2014 2014 Citations: 5
Influence of the project parameters on the LSRM Project optimization VSC Teixeira, DN Oliveira, H Cunha, LLN Reis, RST Pontes 2007 IEEE International Electric Machines & Drives Conference 1, 554-558 , 2007 2007 Citations: 5
Metodologia e projeto de controle de potências para geração eólica e filtragem de corrente harmônica com gerador de indução duplamente alimentado AB Moreira, TAS Barros, VSC Teixeira, PSF Nascimento, E Ruppert CBA2016–XXI Congresso Brasileiro de Automática , 2016 2016 Citations: 4
Controle de potências para geração eólica e filtragem de corrente harmônica com gerador de indução duplamente alimentado AB Moreira, TAS Barros, VSC Teixeira, PS Nascimento Filho, ... An. do VI Simpósio Bras. Sist. Elétricos , 2016 2016 Citations: 4
ER Filho, TA d. S. Barros, AB Moreira,“Design, Optimization and Analysis of the Axial C-core Switched Reluctance Generator for wind power application,” VSC Teixeira Proc. of International Conference on Renewable Energy Research and … , 2015 2015 Citations: 4
Influence of the switched reluctance machines design parameters on its steady-state operation characteristics VSC Teixeira, DN Oliveira, RST Pontes, SA Viana 2007 International Conference on Electrical Machines and Systems (ICEMS … , 2007 2007 Citations: 4
Control of scig based on wind energy conversion system with bess ÂMM dos Santos, RPC Pacífico, NS Costa, MVS de França, VSC Teixeira, ... 2023 IEEE 8th Southern Power Electronics Conference and 17th Brazilian Power … , 2023 2023 Citations: 3
Power control and harmonic current mitigation from a wind power system with PMSG LPS Silva, DV Mota, FP Ruiz, LR Cavalcante, LTP Medeiros, ... 2019 IEEE 15th Brazilian Power Electronics Conference and 5th IEEE Southern … , 2019 2019 Citations: 3
Robustness and ethanol production of industrial strains of Saccharomyces cerevisiae using different sugarcane bagasse hydrolysates VS Teixeira, SPH Azambuja, PH Carvalho, FAA Costa, PR Kitaka, ... Journal of applied biotechnology , 2019 2019 Citations: 3
Controle natural dos lepidopteros desfolhadores de eucalipto em Minas Gerais e Espirito Santo GWG Moraes, PG Brun, LA Soares, VS Teixeira Congresso Brasileiro de Entomologia, Campinas, SP, Brasil, 273 , 1980 1980 Citations: 3
Geradores de reluntância axial com núcleo do tipo C: projeto e acionamento. VSC Teixeira, TAS Barros, AB Moreira, E Ruppert Filho 2017 Citations: 2
MODELAGEM BOND GRAPH E O ENSINO DE ENGENHARIA ELÉTRICA-REPRESENTAÇÃO DAS MÁQUINAS ELÉTRICAS. DN Oliveira, H Cunha Jr, VS de Castro Teixeira ANAIS DO XXXIV COBENGE. Passo Fundo: Ed. Universidade de Passo Fundo … , 2006 2006 Citations: 2
Optimization of power generation using the tip speed ratio method in a wecs equipped with pmsg DDV Mota, ADO Ferro, VSDC Teixeira, LTP Medeiros, LPDS Silva, ... 2023 IEEE 8th Southern Power Electronics Conference and 17th Brazilian Power … , 2023 2023 Citations: 1
Sistema de Geração de Energia Eólica com Filtro Ativo Paralelo a partir do Gerador Síncrono de Imã Permanente Conectado à Rede Elétrica LP de Sousa Silva, D de Vasconcelos Mota, LR Cavalcante, ... Simpósio Brasileiro de Sistemas Elétricos-SBSE 1 (1) , 2020 2020 Citations: 1